Slot size of flakiness index

By Editor

1223.1 1223.2 APPARATUS A. conforming to the design and ...

plate. The size of the slots required for each fraction is given in table 1 below. NOTE: If the material retained on any one of the sieves comprises less than 4% of the total weight of the sample, that material shall be omitted from the flakiness index test. If a 5/8” Flakiness and Elongation - pcte.com.au The accuracy of the slot size is better than 0.1 mm. UTA-0410 Flakiness Index Sieve Set consists of 7 sieves. For sample preparation 6.3, 10, 14, 20, 28, 37.5, 50 and 63 mm aperture sizes test sieves should be ordered separately. TMH1 - Method B3T - CSIR METHOD B3T TENTATIVE METHOD FOR THE DETERMINATION OF THE FLAKINESS INDEX OF A COARSE AGGREGATE SCOPE. The Flakiness Index of a coarse aggregate is determined by gauging screened-out fractions with the appropriate slot(s) given in Table I below. Aggregate retained on the 75 mm and passing the 4,75 mm sieve is not included in the test. Definition. Flakiness sieves, Aggregates testing equipment, Controls Flakiness sieve test set 47-D0415 General description Used to determine if aggregate particles are to be considered flaky, i.e. their thickness is less than 0.6 of their nominal size.

Gilson Flakiness Index Gauges measure particle shape of aggregates used in pavement base course applications or asphalt and concrete paving mixes.

The The Thickness Gauge (Flakiness Index) is made from heavy-gauge stainless steel with precision laser-cut openings and etched size markings for each slot. Part 7 - Aggregates - Department of Transport and Main Roads

Flakiness Index Test procedure for aggregates - Civil4M

Elongation index and flakiness index of coarse aggregate (BS 812 Part:1) Scope: The particle is considered as elongated if its length is more than 1.8 times the mean sieve size of the size fraction to which the particle belongs. Similarly, the particle is considered as flaky if its thickness is less than 0.6 Civil Engineering: Flakiness and Elongation Index of Coarse ... Separation of Flaky material- Each fraction shall be gauged in turn for thickness on a metal gauge of the pattern shown in Fig. 1, or in bulk on sieves having elongated slots. The width of the slot used in the gauge or sieve shall be of the dimensions specified in co1 3 of above Table for the appropriate size of material. GEOTECHNICAL static paint. The accuracy of the slot size is better than 0.1 mm. ORDERING: AG 0101-7 Flakiness Index Sieve Set consists of 7 sieves. TECHNICAL SPECIFICATIONS: • Made of Heavy gauge steel sheets. • Coated with electrostatic paint. MAIN FEATURES: Slot size Weight (approx.) Dimensions AG 0101 4.9x30 mm 1.5 kg 300x220x80 mm Flakiness Sieve Set | SUN LABTEK EQUIPMENTS (I) PVT. LTD.

The accuracy of the slot size is better than 0.1 mm.

Flakiness and Elongation Test (BS 812: Part 3) | seperti layang… Flakiness and Elongation Test. 1.0 Introduction. The type of rocks and the type of crushing machine highly determine the shape and size of the aggregates produced. Elongated and flaky stones are normally not very suitable for road works since the shape and the size make them difficult to compact.